LE-60 AC SOLENOID LOCKS (UNLOCKED WHEN TURNED ON)

LE-60 AC SOLENOID LOCKS (UNLOCKED WHEN TURNED ON) catalogue manual
LE-60 AC SOLENOID LOCKS (UNLOCKED WHEN TURNED ON) catalogue manual

Features

  • The AC type of the solenoid lock.
  • The latch mechanism is incorporated. (auto-locking type)
  • Can be operated with a remote control.
  • Both front and rear surface attachment. (remove the cover when choosing the front surface attachment)
  • Equipped with emergency lock release mechanism for unlocking when not energized. (LE-60-E・ES)
  • Locking/unlocking can be checked the signal. (LE-60-S・ES)

Specification

  • Duty cycle: 100% (continuous rating)
  • Ambient temperature: -5℃ to +40℃ (non-condensing)
  • Operating humidity range: 85%RH or less (non-dewing)
  • Verification switch rated (LE-60-10-S/ES) (resistance load): AC125V, 1A/DC30V, 0.5A

Specific Uses

  • Pass boxes and various cases

Remarks

  • These products are built in varistor.
  • The latch stroke, the retraction force and the extension force are value in the horizontal installation.
  • The rated voltage (continuous rating) is at a power consumption that causes the temperature of the coil to reach 65℃ when the ambient temperature is 40℃.
  • When continuously energized, the solenoid becomes hot (around 70℃). If there is a risk of it being touched, measures should be taken to prevent burns with consideration given to heat radiation.
  • Remove the load on the latch when operating electrically.
  • The construction of the emergency unlocking mechanism requires that the key be pushed in and then turned.